1 / 5

Temperature of SVD2 Be chamber Update 2003/11/27

Temperature of SVD2 Be chamber Update 2003/11/27. Samo Stani č. We monitor the heat taken away by parafin cooling: P[W]=34 * dT [K]. HER. dT(1A)=0.4 deg P meas (I HER =1A)=14W. LER. dT(1.4A)=0.5 deg P meas (I LER =1.4A)=19W. HER+LER. dT(1.1A+1.4A)=1 deg P meas (1A+1.4A)=34W.

sen
Download Presentation

Temperature of SVD2 Be chamber Update 2003/11/27

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Temperature of SVD2 Be chamber Update 2003/11/27 Samo Stanič We monitor the heat taken away by parafin cooling: P[W]=34 * dT [K]

  2. HER dT(1A)=0.4 deg Pmeas(IHER=1A)=14W

  3. LER dT(1.4A)=0.5 deg Pmeas(ILER=1.4A)=19W

  4. HER+LER dT(1.1A+1.4A)=1 deg Pmeas(1A+1.4A)=34W

  5. Estimate of heating power in Be at maximal beam currents T(I) =Tconst +dT(I) T(ILER)= 0.2+0.3 I2 T(IHER)= 0.2+0.4 I2 T(IHER+ILER) between 0.2+0.4 I and 0.2+0.15 I2 dT(ILER= 1A)=0.3 deg dT(ILER=1.4A)=0.5 deg dT(ILER=2.5A)=1.9 deg(65W) dT(IHER=0.6A)=0.2 deg dT(IHER= 1A)=0.4 deg dT(IHER=1.5A)=0.9 deg (30W) dT(1.5A+2.5A)=2.8 deg Pfit(1.5A+2.5A)=95W (was 115W) Pfit(4A) between 55W and 85W