1 / 17

Reducing the occupancies in the calorimeter endcaps of the CLIC detector

Reducing the occupancies in the calorimeter endcaps of the CLIC detector . Suzanne van Dam Supervisor: André Sailer CERN, 6 March 2014. Introduction. Beam-beam interactions Background incoherent pairs Scatter in forward region of CLIC detector H igh occupancy in HCal.

taini
Download Presentation

Reducing the occupancies in the calorimeter endcaps of the CLIC detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reducing the occupancies in the calorimeter endcaps of the CLIC detector Suzanne van Dam Supervisor: André Sailer CERN, 6 March 2014

  2. Introduction • Beam-beam interactions • Background incoherent pairs • Scatter in forward region of CLIC detector • High occupancy in HCal CERN-THESIS-2012-223

  3. Occupancy reduction • The high occupancy has to be reduced • Support tube can provide shielding • Optimize support tube material and thickness

  4. Simulation of occupancy • Simulate background for each geometry • Estimate the occupancy • Need data from a few bunch trains (312 BX/train) • Find number of particles passing through support tube • Correlated to occupancy • Need data from ~10 BXs • Geometrical adaptations to the detector model: • Introduce a scoring plane around support tube • Make support tube geometry variable

  5. Simulation of occupancy • Simulate background for each geometry • Estimate the occupancy • Need data from a few bunch trains (312 BX/train) • Find number of particles passing through support tube • Correlated to occupancy • Need data from ~10 BXs • Geometrical adaptations to the detector model: • Introduced a scoring plane around support tube • Made support tube geometry variable through text file

  6. Contributions to occupancy Energy deposits in HCalendcap • Occupancy per particle type: • Photons and neutrons contribute • Compare to number of hits from different particles in the scoring plane: • Photons have a relatively large impact • Reflect this in the relation between hits in the scoring plane and the occupancy Hits in scoring plane

  7. Figure of merit • To minimize the occupancy, minimize neutron (n) and photon (γ) hits (H) with a relative weight (w) • Assume linear dependence on each particle type • This can be expressed in a figure of merit (FOM): • Weights follow from the ratio of: • Number of energy deposits above threshold and within timing cut in the HCalendcap (N); • Number of hits in the scoring plane (H).

  8. Energy • Energy spectrum for hits in the scoring plane • HCalendcap threshold is 300 keV

  9. Support tube material • Iron photons neutrons

  10. Support tube material • Iron based: • Iron • Stainless steel • Cast iron • Borated steel photons neutrons

  11. Support tube material • Iron based: • Iron • Stainless steel • Cast iron • Borated steel • Neutron moderating and absorbing: • Pure polyethylene (PE) • PE + Li2CO3 • PE + H3BO3 photons neutrons

  12. Support tube material • Iron based: • Iron • Stainless steel • Cast iron • Borated steel • Neutron moderating and absorbing: • Pure polyethylene (PE) • PE + Li2CO3 • PE + H3BO3 • Short radiation length: • Tungsten • Lead photons neutrons

  13. Combine materials • Polyethylene for neutron shielding • Iron-based materials for photon shielding • Tungsten for further photon shielding • To shield both photons and neutrons, materials should be combined.

  14. Combine materials • Polyethylene & stainless steel Total thickness of support tube 100 mm

  15. Combine materials • Polyethylene & stainless steel • Tungsten & stainless steel Total thickness of support tube 100 mm

  16. Summary and conclusions • The high occupancy due to incoherent pairs in the HCalEndcap is caused by neutrons and photons • Photons have relatively more impact on the occupancy • Minimization of the occupancy is based on minimizing the number of particles passing the support tube • Therefore a figure of merit is defined that reflects the higher impact of photons: • Simulations show that • Tungsten is suitable for photon shielding • Polyethylene is suitable for neutron shielding • To shield both neutrons and photons materials should be combined • A high contribution from photon shielding materials is needed

  17. Outlook • Maximize shielding by reducing inner radius of support tube • Use as much tungsten as structural strength allows • For neutron shielding add polyethylene to a structure of tungsten and stainless steel