180 likes | 366 Views
WP 5: Diagnostics Coordinator: Grahame Blair, RHUL. EUROTeV Inaugural meeting, DESY, 1 st November 2004. CFBPM Confocal Resonator BPM. LBPM Laser-based Beam Profile Monitor TRBPM Transformer Beam Position Monitor ESPEC Precision Energy spectrometry
E N D
WP 5: Diagnostics Coordinator: Grahame Blair, RHUL EUROTeV Inaugural meeting, DESY, 1st November 2004 • CFBPM Confocal Resonator BPM. • LBPM Laser-based Beam Profile Monitor • TRBPM Transformer Beam Position Monitor • ESPEC Precision Energy spectrometry • HEPOL Precision High Energy Polarimetry. • TPMON Time and Phase Monitor • WBCM Wide Band Current Monitor • FLUM Fast Luminosity Monitoring
D. ANGAL- KALININ J. CLARKE • Output: • Strong groups, collaborating internationally. • Working prototype systems • International test beam work • RAs, technical staff and students gaining • essential experience. • Aim will be to include the work in the ILC design effort.
Simulations with HFSS and GDFIDL. Position sensitive: compare excitation of modes with zero or maximum on the beam axis. Contact: Volker Ziemann CFBPM: Confocal Resonator Monitor • Uppsala University (+ CERN) • Problem: High frequency waveguide modes perturb measurements with short bunches in CTF3. • Objective: Design and test monitor that interacts with the direct quasi-TEM like field of the bunch, but is insensitive to waveguide modes (wakes). • Idea: Laser resonator does not radiate orthogonally to axis. By reciprocity external fields do not couple into resonator. • Solution: Passive confocal resonator monitor perpendicular to the direction of the beam.
CFBPM Measurable and verifiable.
LBPM Contact: Grahame Blair • Oxford • RHUL • DESY • UCL • CERN PETRA, ATF → Global Collaboration Possible use of GAN systems for remote operation
ESPEC (Cambridge, UCL) Contact: David Miller Design Considerations: • limit SR emittance growth • 360mrad total bend 0.5% • available space in lattice • no modifications necessary, yet • 10m drift space maximum one can consider for mechanical stabilization, alignment • 37m total empty space allows for BPMs outside of chicane to constrain external trajectories • Tiny energy loss before IP Constraints lead to a required BPM resolution of ~100nm (Resolution Stability) Measurement of Luminosity Energy Spectrum: Absolute E (survey, alignment) E jitter (fast BPMs) E dispersion (laserwire?)
Laser amplification cavity for ILC polarimeter HEPOL: Contact: Fabian Zomer • Orsay 500 MHz or 5 MHz 10 nJ/pulse Electron beam 100 fs Pulsed laser Fabry-Perot cavity with Super mirrors Energy gain 104 • Proposed R&D : • Resonance of a high gain Fabry-Perot Cavity with a fs laser • Realization of a specific confocalcavity
TRBPM: Transformer beam position monitor Contact: Lars Soby Develop a BPM with <100 nm resolution, <10 µm precision, <15ns rise-time, with an aperture >4 mm for beam position monitoring in LC main beam and beam delivery system with the performance required from beam dynamics studies. • CERN TPMON: Precision beam phase measurement Contact: Jonathan Sladen • Precise phase stability of the main beam with respect to the RF is required for all linear colliders. • CLIC requires the phase error to be less than 15fs rms in order to limit luminosity loss. • This precision is more than an order of magnitude better than has currently been achieved both for phase reference distribution and for beam/RF phase measurement. • Both strategy and technology need to be found.
CERN WBCM: Button PU Contact: Lars Soby Wide band beam current pick-up Develop a beam current monitor with 20 GHz bandwidth for measurement of intensity and longitudinal position bunch to bunch Provide a signal for machine set-up and for equalizing bunch-charge and -spacing. consist of 4 D=1.6mm buttons, from which the beam position and approximate intensity is derived. Can be used either as a standard PU or as a relative phase measurement along the pulse Applicable to LC main beams, drive beams and damping rings.
CERN WBCM: ElectrostaticPU Contact: Lars Soby 100µs time constant → PU capacitance of order 100pF. dielectric constant >> 1 thickness of order 1mm. 4 electrodes: The special form of the cuts enhances linearity. electrode length ~ 50mm (2nF/m) output voltage ~ 4V Used to measure the overall pulse position
TRBPM WBCM TPMON
DESY FLUM Contact: Wolfgang Lohman Studies of fastbeamstrahlung monitorfor IP beam characterisation V. Drugakov, ECFA workshop
WP5 Summary • DIAG work package includes a range of systems important to the ILC. • A strong input also from university groups. • Wide range of diagnostics with challenging objectives. • Deliverables include many prototype systems, bench tests and beam test results. • Lots of interplay with the other WPs An interesting and challenging 3 years ahead of us