1 / 21

RinNOVA IN CIRCUITI IDRAULICI

RinNOVA IN CIRCUITI IDRAULICI. SCHEMA IDRAULICO. Tre vie in riscaldamento. Tre vie in sanitario. CIRCOLATORE. COMPITO IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO DATI UNICO MODELLO: WILO INT TWP 12/6 – 76 W

Download Presentation

RinNOVA IN CIRCUITI IDRAULICI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RinNOVA IN CIRCUITI IDRAULICI

  2. SCHEMA IDRAULICO Tre vie in riscaldamento Tre vie in sanitario

  3. CIRCOLATORE • COMPITO • IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO • IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO • DATI • UNICO MODELLO: • WILO INT TWP 12/6 – 76 W • ALIMENTATO A 230 Vc.a. • COCLEA INGLOBATA NEL GRUPPO DI RITORNO

  4. VASO D’ESPANSIONE • COMPITO • COMPENSA L’AUMENTO DI PRESSIONE DETERMINATO DALL’AUMENTO DI TEMPERATURADELL’ACQUA NELL’IMPIANTO DI RISCALDAMENTO • DATI • CAPACITA’ TOTALE 7 LITRI • PRESSIONE DI PRECARICA 1 bar • RACCORDO IDRAULICO 3/8 • CONTENUTO MASSIMO D’ACQUA NELL’IMPIANTO 109 LITRI

  5. SCAMBIATORE PRIMARIO • COMPITO • TRASFERIRE IL CALORE DELLA COMBUSTIONE ALL’ACQUA CHE LO ATTRAVERSA • CARATTERISTICHE • INTERAMENTE IN RAME • RISPETTO LA VERSIONE PRECEDENTE HA UN TUBO CURVO DI ENTRATA ED USCITA PER RIDURRE LE PERDITE DI CARICO. • COMPOSTO DA 8 TUBI OVALI MOLTO PIATTI(OLTRE IL 90% DI SUPERFICIE) • 2 MODELLI • 24KW da 73 alette di scambio L 301 • 28/32 KW da 97 alettedi scambio L 369 L

  6. NTC RISCALDAMENTO NTC RISCALDAMENTO E TERMOSTATO SICUREZZA SONDA DI TEMPERATURA A 4 POLI (2 NTC DISTINTI) POSTA SULL’USCITA DELLO SCAMBIATORE PRIMARIO • NTC 1: COMUNICA ALLA SCHEDA LA TEMPERATURA DI USCITA DELL’ACQUA DALLO SCAMBIATORE PRIMARIO TRADUCENDOLA IN UN SEGNALE ELETTRICO PER: • GESTIONE MODULAZIONE RISCALDAMENTO • CONTROLLO CIRCOLAZIONE CIRCUITO PRIMARIO (VERIFICA DELLA VELOCITA’ DI INCREMENTO DELLA TEMPERATURA) • NTC2: COMUNICA ALLA SCHEDA LA TEMPERATURA DI USCITA CHE BLOCCHERA’ LA CALDAIA LA LA TEMPERATURA SUPERA I 105°C (BLOCCO TERMICO E02)

  7. GRUPPO ACQUA -VERSIONE MISTA MOTORE VALVOLA 3 VIE TRASDUTTORE DI PRESSIONE FLUSSIMETROSANITARIO VALVOLA 3 BAR CON RUBINETTO DI SCARICO NTCSANITARIO ELETTROVALVOLA DI RIEMPIMENTO IDROMETRO

  8. GRUPPO RITORNO • GRUPPO DI RITORNO • POSIZIONATO SULLA PARTE DESTRA DELLA CALDAIA • COMPOSTA DA 2 SOTTOGRUPPI: • CORPO COCLEA+TRE VIE: • VALVOLA TRE VIE (otturatore e motore) • VALVOLA TRE VIE • BY PASS • COCLEA POMPA • VALVOLA 3 BAR E SCARICO IMPIANTO • VALVOLA JOLLY • RITORNO RISCALDAMENTO • CORPO ENTRATA SANITARIO: • RUBINETTO DI RIEMPIMENTO MANUALE • ELETTROVALVOLA DI RIEMPIMENTO • FLUSSIMETRO SANITARIO • ENTRATA ACQUA SANITARIA

  9. GRUPPO RITORNO MOTORE TRE VIE VALVOLA 3 BAR + SCARICO IMPIANTO CORPO ENTRATA SANIATRIO CORPO COCLEA + TRE VIE FLUSSIMETRO SANITARIO OTTURATORE TRE VIE RUBINETTO DI RIEMPIMENTO MANUALE ELETTROVALVOLA DI RIEMPIMENTO MOTORE POMPA

  10. GRUPPO RITORNO TRE VIE IN RISCALDAMENTO MANDATA ALLO SCAMBIATORE PRIMARIO MANDATA IMPIANTO RISCALDAMENTO RITORNO IMPIANTO RISCALDAMENTO

  11. GRUPPO RITORNO – VALVOLA TRE VIE TRE VIE IN SANITARIO MANDATA ALLO SCAMBIATORE PRIMARIO ACQUA SANITARIA RITORNO PRIMARIO DA SCAMBIATORE SANITARIO

  12. GRUPPO RITORNO – VALVOLA TRE VIE CIRCUITO SANITARIO CIRCUITO PRIMARIO MANDATA ALLO SCAMBIATORE PRIMARIO ACQUA SANITARIA MANDATA IMPIANTO RISCALDAMENTO RITORNO PRIMARIO DA SCAMBIATORE SANITARIO RITORNO IMPIANTO RISCALDAMENTO

  13. GRUPPO DI MANDATA • COMPITO • IN BASE ALLA POSIZIONE DELLA VALVOLA TRE VIE IL CIRCUITO PRIMARIO VIENE DEVIATO ALLA MANDATA RISCALDAMENTO O ALLO SCAMBIATORE SANITARIO DALLO SCAMBIATORE PRIMARIO ALLO SCAMBIATORE SANITARIO MANDATA RISCALDAMENTO ALLA MANDATA RISCALDAMENTO DALLO SCAMBIATORE PRIMARIO

  14. GRUPPO RITORNO – VALVOLA TRE VIE • COMPITO • DEVIA IL FLUSSO DEL CIRCUITO PRIMARIO IN BASE ALLA RICHIESTA IN ATTO • CARATTERISTICHE • MONTATA SUL RITORNO • COMPOSTA DA: • MOTORE BITRON “COMPATTO”: CORSA 10 mm • GRUPPO OTTURATORI (SENZA MOTORE POSIZIONE A RIPOSO IN RISCALDAMENTO) • COMMUTA IN RISCALDAMENTO SOLO CON RICHIESTA IN ATTO • MONTATA SUL RETRO DEL BLOCCO POMPA: • CON RICHIESTA DI SANITARIO O STAND BY E’ APERTO IL RITORNO DEL CIRCUITO PRIMARIO DALLO SCAMBIATORE PRIMARIO • CON RICHIESTA DI RISCALDAMENTO E’ APERTO IL RITORNO DALL’IMPIANTO TERMICO

  15. GRUPPO DI RITORNO – MOTORE TRE VIE • Celeste = comune • Nero = Riscaldamento • Marrone = Sanitario RISCALDAMENTO SANITARIO

  16. GRUPPO RITORNO – VALVOLA 3 BAR • COMPITO • VALVOLA DI SOVRAPRESSIONE CHE SCARICA AUTOMATICAMENTE IL CIRCUITO PRIMARIO NEL CASO DI SOVRAPRESSIONE • CARATTERISTICHE • INTERVENTO AUTOMATICO CON P > 3 bar • LA STESSA VALVOLA FUNGE ANCHE DA RUBINETTO DI SCARICO MANUALE GHIERA DI APERTURA VALVOLA DI SCARICO MANUALE

  17. GRUPPO DI RITORNO – BY PASS • COMPITO • COMPONENTE DI SICUREZZA CHE GARANTISCE UN CORRETTO FLUSSO D’ACQUA SUL SCAMBIATORE PRIMARIO INDIPENDENTEMENTE DALLE CONDIZIONI DI CARICO DELL’IMPIANTO DI RISCALDAMENTO • CARATTERISTICHE • AUTOMATICO NON TARABILE • DI SERIE SU TUTTE LE CALDAIE • MONTATO SUL GRUPPO DI RITORNO (CORPO DEVIAZIONE-COCLEA) BY PASS

  18. GRUPPO RITORNO – CORPO ENTRATA SANITARIO • COMPITO • GESTIONE ENTRATA ACQUA SANITARIA • COMPRENDE • FLUSSIMETRO SANITARIO (MODELLO SPECIFICO PER M291) • GRUPPO RIEMPIMETO: • RUBINETTO RIEMPIMENTO MANUALE • ELETTROVALVOLA PER CARICO SEMIAUTOMATICO (DA COMANDO REMOTO) FLUSSIMETRO SANITARIO RUBINETTO DI RIEMPIMENTO MANUALE ELETTROVALVOLA DI RIEMPIMENTO CANALE BY-PASS RUBINETTO CARICO MANUALE

  19. GRUPPO DI MANDATA • GRUPPO DI MANDATA • POSIZIONATO SULLA PARTE DESTRA DELLA CALDAIA • IN BASE ALLA POSIZIONE DELLA VALVOLA TRE VIE L’ACQUA PUO’ ANDARE O ALLA MANDATA RISCALDAMENTO O ALLO SCAMBIATORE SANITARIO • MATERIALE COMPOSITO; GRUPPO COMPOSTO DA: • TRASDUTTORE PRESSIONE IMPIANTO • NTC SANITARIO • RACCORDO MANDATA RISCALDAMENTO • RACCORDO USCITA ACS • PRESA PRESSIONE IDROMETRO TRASDUTTORE PRESSIONE IMPIANTO NTC USCITA ACS ALLO SCAMBIATORE SANITARIO MANDATA RISCALDAMENTO USCITA ACS ALLA MANDATA RISCALDAMENTO DALLO SCAMBIATORE PRIMARIO

  20. GRUPPO MANDATA: TRASDUTTORE - NTC SANITARIO TRASDUTTORE DI PRESSIONE • SENSORE ELETTRICO PER LA LETTURA DELLA PRESSIONE ACQUA NEL CIRCUITO PRIMARIO DELLA CALDAIA. • CON P< 0,35 Bar: ANOMALIA SPECIFICA SU DISPLAY(E04) • STESSO MODELLO DI M290 NTC USCITA ACS • CONTROLLARE LA TEMPERATURA DI USCITA DELL’ACQUA CALDA SANITARIA • TRADUCE LA TEMPERATURA DELL’ACQUA IN SEGNALE ELETTRICO • STESSO MODELLO DI M290

  21. SCAMBIATORE SANITARIO • COMPITO • PRODURRE ACQUA CALDA SANITARIA ATTRAVERSO UNO SCAMBIO TERMICO ACQUA-ACQUA • CARATTERISTICHE • REALIZZATO CON PIASTRE IN ACCIAIO • GEOMETRIA A NIDO D’APE DELLE SUPERFICI DI SCAMBIO PER ELEVATA EFFICIENZA • NON COMPATIBILE CON I PRECEDENTI MODELLI (INTERASSI DIVERSI) • DATI • N° 12 PIASTRE 24 KW • N° 14 PIASTRE 28 KW • N° 16 PIASTRE 32 KW

More Related