Hodoscope Replacement for E906

Hodoscope Replacement for E906. By Rusty Towell December 8, 2006. Outline. Why Hodoscopes Detector description Scintillator material Photomultiplier tubes Schedule The hodoscope group. Hodoscopes . Used for triggering like in E866. Upgrades in design Additional planes

vernon-kidd
Download Presentation

Hodoscope Replacement for E906

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hodoscope Replacement for E906 By Rusty Towell December 8, 2006

  2. Outline • Why Hodoscopes • Detector description • Scintillator material • Photomultiplier tubes • Schedule • The hodoscope group Review of FNAL E906

  3. Hodoscopes • Used for triggering like in E866. • Upgrades in design • Additional planes • More selective trigger • efficiency monitoring • redundancy • New material (higher efficiency) • Double ended read-out (better timing needed due to the higher rates) Review of FNAL E906

  4. Hodoscope Planes(approximately the same sizes, changes highlighted)E866 E906 Review of FNAL E906

  5. Typical y Hodoscope Plane St 1 and 2 16 channels y 2 half planes x Review of FNAL E906

  6. Double-ended y Hodoscope Plane St 3&4 y Half planes at slightly different z positions to allow for double-ended readout. x Review of FNAL E906

  7. Scintillator Material • Old material is: • Too small (station 1) • Too thin (station 2) • Too old/crazing • station 2 (1989) • station 3 & 4 (1982) • Decreased efficiencies were observed in E866. • Therefore ‘new’ scintillator material and light guides will be used. • Material for stations 1 and 2 will come from HERMES. • New material will be purchased for stations 3 and 4. Review of FNAL E906

  8. Photomultiplier Tubes • Total number of PMTs needed for E906 is 384 plus spares. • Reuse all good PMTs from E866. Total number of tubes was 198. • An additional 250 tubes have been committed from ZEUS when DESY is decommissioned in fall 2007. • All tubes will be tested. Review of FNAL E906

  9. Hodoscope Budget • Scintillator and light guide material: • Scintillator: EJ-200 (same as Bicron BC-408) • estimated at $120 k plus contingency and inflation based on a 2002 quote. • Updated quote received late last week came in slightly lower. • Total budgeted is $153 k from DOE and $ 16 k from NSF. • Photomultiplier tubes • All pmt’s will be reused from previous experiments. • The only costs will be in shipping and testing the tubes. • Total budgeted is 2k $. Review of FNAL E906

  10. Schedule • Most of the labor intensive work on the hodoscopes (especially on station 3 and 4) will be done during the summer break from classes. • PMTs testing, design work, purchases, etc. can be done during the school year. • There should be no problem in completing the hodoscopes on time. • The hodoscopes could be completed earlier if the funding profile allowed for materials to be purchased sooner. Review of FNAL E906

  11. Hodoscope TeamUIUC & ACU • UIUC will rebuilt stations 1 and 2. • ACU will rebuilt stations 3 and 4. • ACU rebuilt and commissioned the hodoscopes for E789 and E866. • Testing of the PMTs will be shared. • This team can construct the hodoscopes needed for E906. Review of FNAL E906