1 / 13

3051SMV Transition

3051SMV Transition. Agenda. Transition to the 3051SMV: 3095M-HART Discontinuance 3095M-HART Final Order Date Models Affected 3051SMV Feature Improvements 3095M-HART Comparison Flowmeter Offering Engineering Assistant Support Summary. Transition to the 3051SMV from the 3095M-HART.

zinnia
Download Presentation

3051SMV Transition

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3051SMV Transition

  2. Agenda • Transition to the 3051SMV: 3095M-HART Discontinuance • 3095M-HART Final Order Date • Models Affected • 3051SMV Feature Improvements • 3095M-HART Comparison • Flowmeter Offering • Engineering Assistant Support • Summary

  3. Transition to the 3051SMV from the 3095M-HART • Since the release of the 3051SMV in Oct. 2009, market led transition was expected • 3051SMV has higher performance and more features • Transition time-frame shortened by Japanese crisis • Earthquake and resulting tsunami destroyed a supplier’s factory • Supplier has decided to discontinue the component • Timeframe to redesign unacceptable • No other 3095 or Rosemount products are affected 40% of customers already transitioned

  4. 3095M-HART Final Order Date • Final Order Date: July 29, 2011 • Orders will ship at standard lead-times • Service and warranty requests will be honored with remaining 3095M-HART inventory or an upgrade to 3051SMV • Option to upgrade at the cost to repair a 3095M through for two years or five years from the original shipment date of device, whichever comes first

  5. 3095M-HART Models To Be Transitioned • 3095MA HART Transmitters • 3095MAxxxxxxxxxxxxx… • NOT Affected: • 3095MV FOUNDATION fieldbus • 3095FB MODBUS • 3095MFx HART Flowmeters • 3095MFAxxxxxxxxxxxxxxxxxAxx... • 3095MFCxxxxxxxxxxxxxAxx… • 3095MFPxxxxxxxxxxxxxxxAxx… • NOTAffected: • 3095MFx FOUNDATION fieldbus Flowmeters 3095MA HART 3095MFC 3095MFP 3095MFA

  6. Rosemount 3051S MultiVariable HART Transmitter Joule Thomson Correction Energy and Mass or Actual Volumetric Flow Sensor Matching with Callendar-van Dusen Easy 2 Step Configuration Ultra For Flow Real-time compensation of over 25 variables @ 22 updates/second User specified temperature limits and temperature backup % Reading Scalable Compensation Terminal block temperature wiring 10 ±0.1% Span 9 3051C 8 3051S Ultra 7 Ultra for Flow 6 Flow Turndown 5 4 3 2 1 0 10:1 5:1 3:1 2:1 1:1

  7. Integrated Flowmeters Available With the 3051SMV 3051SFx Flowmeters Offer Equivalent 3095MFx Features • Fully Assembled, Configure, Leak Tested • Annubar, Compact Orifice, and Integral Orifice • Integral Temperature option 3051SFP 3051SFC 3051SFA

  8. Transitioning to the Rosemount 3051SMV Improves Flow Measurement • 3051SMV: Superior Flow Measurement • Improved Mass and Energy Flow Calculations • Scalable Measurement Options for Liquids and Saturated Steam • Easy Start-up and Simplified Maintenance with Engineering Assistant 6.1.1

  9. 3051SMV vs. 3095M-HARTPhysical Comparison 3051SMV • Coplanar Connection • Height: 8.53-in. (217 mm) • 1.46-in. (37 mm) taller • Weight: 6.7 lbs (3.0 kg) • 0.7lb (0.3 kg) heavier • Temperature Connection • Terminal Block 3095M-HART • Coplanar • Connection • Height: 7.07-in. • (180 mm) • Weight: 6.0 lbs (2.7 kg) • Temperature Connection • Temperature Boss

  10. 3051SMV vs. 3095M-HARTDimensional Comparison 3051SMV 3095M-HART

  11. Engineering Assistant Support EA 6.1.1 • For 3051SMV • Stand alone • AMS SNAP-ON planned • Full listing of fluids • Most primaries supported • Ongoing maintenance releases for new capabilities • EA 5.5.1 • For 3095M • Stand alone • powered by AMS • AMS SNAP-ON • Full listing of primary elements and fluids • Available to support legacy installations Both versions will continue to be available

  12. Start Your Transition to the 3051SMV Transmitter and Flowmeters Today • REMEMBER: Last Order Date for 3095M-HART • July 29, 2011 • 3051SMV Offers Equivalent 3095M-HART Features and More: • Superior Flow Measurement Performance • Improved Temperature Measurement • Fully Integrated Flowmeters 3051SFP 3051SFC 3051SFA

More Related