1 / 20

TRD straws status report from 14/03/2012 + AMS-02 acceptance for lepton flux

TRD straws status report from 14/03/2012 + AMS-02 acceptance for lepton flux. N. Nikonov. TRD occupancy monitoring for last week. Straw inefficiency example for aligned TRD (pass4 stream). TRD straws inefficiency vs. time. TRD gas refill 21-22 Dec 2011.

astrid
Download Presentation

TRD straws status report from 14/03/2012 + AMS-02 acceptance for lepton flux

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TRD straws status reportfrom 14/03/2012+AMS-02 acceptance for lepton flux N. Nikonov

  2. TRD occupancy monitoring for last week

  3. Straw inefficiency example for aligned TRD (pass4 stream)

  4. TRD straws inefficiency vs. time TRD gas refill 21-22 Dec 2011

  5. Conclusions and “To do” list for TRD occupancy monitor • General work is already finished • Automatic every week processing requires machine which can submit jobs use crontab. • Evaluation can be done on daily basis, however, for statistical reason it’s better to have not less than 4 days. • The method works now on 1 week basis, which supposed to be enough. • Time – dependence of straw inefficiency was done for first half year of data taking use B620 pass4 stream. • To be continued till March 2013. • 2013 studies can be done on std stream as well as weekly reports since method is robust and can find bad straws even if TRD is not aligned.

  6. AMS-02 acceptance check and studies for lepton analysis • From MC we measure: • GF of sensitive trigger volumes X Trigger efficiency X TrTrack efficiency. • From ISS data we can estimate: • Trigger efficiency for selected particle sample use Tof ¾ unbiased trigger • TrTrack efficiency use other detectors: ECAL for energy measurement, ToF, TRD to check if particle passed trough the tracker. • A question: How we can rely on MC? • The answer is: Let’s factorize problem • We can define “acceptance planes”: TrTrack – 9 planes, Tof – 4(2) planes, TRD – 2 planes, Ecal – 2 planes and store in preselection (x,y) of MaxSpan Track. • Make simple ToyMC, where only magnetic field involved and evaluate pure GF of this set of planes. • Since G4 doesn’t change particle ID due to Bremsstrahlung, ionization etc. , one can calculate: • GF pure on toymc X Trigg efficiency (ISS) X Trk efficiency (ISS) • This value should be the same what we have from MC. • The difference will give us understanding of systematic

  7. Towards acceptance definition: TRK(source: TkDBc) Z=158.92 Z=53.06 Z=29.228 Z=-2.318 Z=25.212 Z=1.698 Z=-25.212 Z=-29.228 Z=-135.882

  8. Towards acceptance definition: TOF(source: TofDBc) Z1=64.425 Z2=65.975 Z1=61.325 Z2=62.875 Z1=-64.425 Z2=-65.975 Z1=-62.875 Z2=-61.325

  9. Towards acceptance definition: TRD(source: AC::AMSGeometry) Layer 0 Layer 20 Z= 86.1 Z=141.2

  10. Towards acceptance definition: ECAL(source: group A preselection) Z1= -142.792 Z2 =-158.457 (Exit_in_32_4 && Entry_in_32_4) && ( Exit_in_31_5 || Entry_in_31_5 )

  11. Acceptance planes summary: • Here is a full list of Z which we have to store in particle and efficiency sample selection: • We have to agree to use max span tracks to check acceptance criteria: • trk_track->iTrTrackPar(1,3,3); 21 pair of (x,y) at given Z has to be stored

  12. How detector’s dimensions matches preselected data? Gaps here are due to ECAL geometry cuts in preselection • Inefficiency due to dead ladders. Should we cut these events? • Probably not because: • Flux isotropy, we calculate average efficiency • We enlarge border length, possible border issues • We wish to keep more statistics • Probably yes: • Quality of the fit will be better if we have more points

  13. ToyMC for GF evaluation. Generation surface Generation surface: cylinder, R=110 cm, z[53.06, 170], GF = 37.3 m2 sr

  14. ToyMC for GF evaluation. Simple tests • Measurement of GF for plane with known area • Measurement of GF for telescope with 2 circular and rectangular shapes: b2 a2

  15. ToyMC for GF evaluation. AMS-02 acceptance planes Geometric factors for various detector sets and acceptance planes combinations (in cm2 sr)

  16. ToyMC checks: TOF 4/4 * TRD * ECAL * Trk Inner (all) • This picture should corresponds to our preselection, • some differences due to: • finite rigidity of ISS particles (smoother edges) • not isotropic yet (no cutoff requirement) • toy mc has no “dead” TRK ladders

  17. ToyMC checks: TOF 4/4 * TRD * ECAL * Trk Inner * !L9 * L1

  18. ToyMC checks: TOF 4/4 * TRD * ECAL * Trk Inner * !L9 * !L1

  19. ToyMC checks: TOF 4/4 * TRD * ECAL * Trk Inner * L9 * L1

  20. ToyMC next step. Adding magnetic field

More Related