An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. REXIS Detector Packaging and Assembly Harrison Bralower REXIS Engineering Peer Review 9/18/12

  2. What is OSIRIS-REx? • The Origins, Spectral Interpretation, Resource Identification, (and) Security REgolith eXplorer is a NASA New Frontiers mission to asteroid 1999 RQ36 • Asteroid has a heliocentric orbit that intersects Earth’s orbit; it can usually be found between here and Mars • 1-in-1000 chance asteroid hits Earth in 2169 • OSIRIS-REx Mission objectives • Return at least 60g of asteroid regolith to Earth and characterize the sample in situ • Globally map the asteroid topology and mineralogy • Measure orbital perturbations due to Yarkovsky effect • Compare data to ground measurements of other nearby asteroids • REXIS is a Class-D student payload onboard OSIRIS-REx Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  3. What is REXIS? Coded Mask • REgolith • We study asteroid dust • X-ray • We monitor X-rays fluoresced out of the asteroid by incident solar X-rays (which we also monitor) • Imaging • We use CCDs to capture images of the asteroid and create a global map • Spectrometer • We identify spectral lines in the collected X-rays to determine the chemical composition of the asteroid Radiation Cover Detector Array DASS Radiator Electronics Box Thermal Isolation Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  4. REXIS Science Mission Sun • We want to identify the distribution of carbon on the surface of RQ36 with a spatial resolution of 50m or better • Problem: Our CCDs cannot detect carbon emission lines—too low energy • We can indirectly determine the carbon content by measuring distribution of other elements • O, Mg, Fe, Al, Si, S with SNR > 10 • These all emit X-rays between 0.5-10keV, which the REXIS CCDs can detect with high quantum efficiency and spectral resolution • Monitoring solar X-rays provides context for X-rays measured off the asteroid RQ36 Solar X-rays X-ray Fluorescence (XRF) Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  5. Coded-Mask Imaging • Consider a mask pattern in front of the detectors • Photons from any direction cast a shifted shadow of the mask pattern onto the detectors • Intensity of shifted pattern corresponds to how bright that direction is in the field of view • Simple ray-tracing algorithms can determine what all possible shifted patterns look like • Spatial cross-correlation of data and mask pattern reveals the most statistically likely direction of incident X-rays Detector Plane Image Coded Aperture Mask Reconstructed Image

  6. CCD Thermal Environment Asteroid QIR & QAlbedo QSolar QRadiation Sun Radiator Sun Shield Heat Strap (DASS to Radiator) QPower QParasitic EB CCDs OSIRIS-REx S/C Deck Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  7. Thermal Requirements • Each CCD must dissipate ~61mW of heat (TBR) • Asteroid IR and albedo, intra-instrument radiative exchange, power to operate the CCDs, and parasitic conduction from electronics • Science requirements demand CCDs remain at -60°C or colder • Data thrown out at temperatures above -50°C • CCDs are passively cooled via conduction through DASS and thermal strap to radiator, which radiates to deep space • Instrument position on spacecraft deck has been an issue • We believe the radiator can reach -70°C, which leaves 10°C of conduction losses, contact resistances, and margin

  8. Lincoln Labs CCID-41 • Heritage dating to ACIS (CCID-17) and Astro-E2 (CCID-41) • Designed for X-ray applications • 1024 x 1024 pixels • 24µm x 24µm pixel size • Consistent with L3 specs • Split frame-store • Back-illuminated • Covered with 220nm aluminum for optical blocking • Supports charge injection • REXIS uses a 2 x 2 array of these CCDs Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  9. CCD Packaging Options • Lincoln can provide different packaging options depending on the application • Invar pedestal • Used for tight-tolerance applications • Invar can be heat-treated to match the CTE of silicon • Kovar/alumina ZIF socket • Used primarily for development applications in a lab setting • Ceramic package • Used for looser-tolerance applications • Cheapest and easiest to produce • Custom packaging(e.g. integrating mechanical and electrical interfaces in one structure for PanSTARRS) Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  10. REXIS Packaging Trade • Invar package is tighter tolerance than we need • Coded-mask imaging is very robust against misalignment and other error sources • Invar is heavy and has poor thermal conductivity • Kovar/alumina ZIF package isn’t really intended for flight • Kovar is heavy • Would require custom ZIF socket or other connector • Thermal management would be very difficult • CCDs not replaceable • Package not rated below -40C; REXIS operates at -60C • CCDs already ship in alignment • Ceramic package is (relatively) simple • Low mass (4 packaged ACIS CCDs have a total mass of ~200g) • Easy to connect to electronics since we pick the connectors • CCDs are individually replaceable • Thermal management much simpler • Rated to -80C • Harder to align—each CCD must be in alignment individually

  11. REXIS Packaging Design • What does REXIS need in a detector package? • Low mass • Good CTE match to silicon • Easy alignment • Replaceable CCDs • Low thermal resistance • Launch survivability • ACIS heritage package meets most of these requirements Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  12. REXIS Packaging Design • Design is almost exactly the same as ACIS package • Some design elements subjected to trades or redesign • Ceramic substrate material • Metal parts material • Flexprint design Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  13. Detector Assembly Requirements • What do we need in a detector assembly? • Abutment gap of an integer multiple of 384µm • Low mass • Low thermal resistance • Keep CCDs aligned with respect to each other and the mask • Protect CCDs from radiation damage • Shield frame-store from incident photons • Minimize stray light from striking CCDs • Provide means of checking CCD degradation in flight • Fit within existing REXIS footprint (if possible) • Provide breakout of CCD electrical connections to electronics • Must not fluoresce in detectable range • All aluminum parts in field of view will be gold-coated

  14. Detector Assembly Requirements • Distance between active imaging areas of CCDs an integer multiple of 384µm • REXIS bins single 24µm x 24µm pixels into 16 x 16 superpixels • Gaps in data should be an integer multiple of superpixel size • Actual gap between packages is smaller due to inactive silicon on die edges • Maximum misalignment requirements • ΔX/ΔY translational shift (in detector plane): ±0.0384cm • ΔZ translational shift (normal to detector plane): +6.67/-4.00cm • Rotational shift about X and Y: ±1.54° • Rotational shift about Z: ±0.40° • All mechanical parts must have first natural frequency >90Hz • All mechanical parts must survive launch • Will perform launch load and vibration analysis before PDR

  15. REXIS Detector Assembly Flexprint Attachment Points Fe-55 Check Source Tee (bonded to CCD package) Active Imaging Area “Fun Part” Flexprint Slot Radiation Shield Alignment Pin Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  16. Thermal Model of Assembly Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  17. Ceramic Substrate Trade • Two metrics: CTE match to silicon and thermal conductivity • Cost not an issue for this part • Substrate thickness still open trade • Nominally 1/8” from ACIS heritage • Need to do shock/vibration analysis to find minimum substrate thickness Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  18. Ceramic Substrate Trade

  19. Metal Parts Trade • Detector assembly has three metal parts (not including radiation shielding) • Tee (bonded to package) • Array structure (holds CCDs and is screwed into the DASS) • “Fun Part” (screwed into array structure and bonded to CCD package with RTV epoxy) • Considered two materials: Beryllium and aluminum • Plot on previous slide includes only aluminum parts in model • ΔT across DAM lower than expected • Beryllium provides lower mass, higher thermal conductivity, and better CTE match to other parts at significant risk to project • No justification for using beryllium in design

  20. Fe-55 Check Source • CCDs degrade with exposure to space environment • Spectral lines shift in mean energy and become broader with time • Installing a known radiation source in the assembly can be used for in-flight calibration and monitoring of CCD health • Fe-55 is a very common laboratory radiation source • Fe-55 has peaks at 5.9keV and 6.4keV, which can be used to check CCD performance against requirements set at 6keV • Requirements for check source • Must not radiate towards other instruments on OSIRIS • Must provide enough counts (3kBq source chosen) • Must only illuminate 8-16 pixels on CCD edge so as not to contaminate asteroid data

  21. REXIS Detector Assembly Radiation Shield Collimator Abutment Gap Fe-55 Source Pockets for Mass Reduction Shim Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  22. Radiation Cover Hinge Frangibolt Aluminum Cover Weak Point Titanium Bolt Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  23. Radiation Damage • All electronics in flight require shielding from ionizing and non-ionizing radiation • Most chips will latch up or fail • CCDs degrade instead • Non-ionizing radiation will displace silicon atoms from crystal lattice and create high-energy electron traps • Decreases charge transfer efficiency (CTE) in CCDs, which shows up as a gain decrease • To first order, CCDs will record sum of actual and gain-shifted peaks • As gain shift increases with damage, spectral lines get broader Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  24. Radiation Damage • Spectral lines widen until science requirements are violated • Charge injection will delay this • Data from Astro-E2 relates change in CTE to radiation dose for REXIS CCDs • By finding lowest tolerable CTE we can find the maximum acceptable dose and size the shield • Current depth: 5.5mm (TBR) Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  25. Flexprint Cable Requirements • Low mass • High thermal resistance • Circuit remains out of CCD FoV • Mounts to detector assembly • Must survive launch • Must provide strain relief on flexprint • No vias on CCD end • Kavli has shownvia failure under thermal cycling • Shielded video output/frame-store lines • May not appear in Gerber files • Glenair 890-011 37-pin Nanominiature connector • .725”(L) x .125” (W) x .255”(D) Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  26. Flexprint Cable Design • This circuit delivers analog video through output JFETs to the detector electronics • Also contains reverse-protection diodes and filter capacitors, plus an RTD for monitoring CCD temperature • Four layers • Smaller and more compact than Astro-E2 flexprint • Output connects to electronics box via connector saver • Routed either through DASS or out truss side panels—trade still open 4-Wire RTD 2-56 Through Holes Output Protection Diodes Connector Regolith X-ray Imaging Spectrometer – REXIS – Detector Packaging Peer Review September 18, 2012

  27. Questions?