1 / 15

multi-turn extraction tracking simulation for JPARC-MR

multi-turn extraction tracking simulation for JPARC-MR. A. Ando, T. Koseki, S. Mihara, N. Saito, A. Sakumi * , K.Satoh, M. Tomizawa and M. Tawada KEK *) Univ of Tokyo 2008.06.12 BNL g-2 meeting. Introduction JPARC-MR. Circumference 1567.5m with 3-116m long straight sections.

bary
Download Presentation

multi-turn extraction tracking simulation for JPARC-MR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. multi-turn extraction tracking simulation for JPARC-MR A. Ando, T. Koseki, S. Mihara, N. Saito, A. Sakumi*, K.Satoh, M. Tomizawa and M. Tawada KEK*) Univ of Tokyo 2008.06.12 BNL g-2 meeting

  2. Introduction JPARC-MR • Circumference 1567.5m with 3-116m long straight sections. • 3.3x1014 protons per pulse (15uA) full beam power: 750kW at 50GeV • Extraction energy: 30 GeV (Phase-I) • Emittance 10 pi mm-mrad (design) @30 GeV

  3. Introduction JPARC-MR • May 22, 2008 3Gev proton beams were successfully injected to JPARC-MR. • Beam were captured by RF and dumped after 1000 turns. • Acceleration to 30 GeV and beam extraction will start in the end of this year.

  4. Purpose of this simulation • Split a beam into 5 or 4 beams in transverse phase space in JPARC-MR. • We want to study the following issues by using simulation. • Can nonlinear elements create stable islands in JPARC-MR? (Do higher order components degrade the islands?) • Is there enough beam separation space for extraction? • Can the fraction of each beam be equal? • How much is the beam loss at septum magnet? • Estimate machine error tolerances.

  5. Simulation model • MR lattice: FODO • Sextupole magnets which are used for chromaticity corrections are included. • Higher order multi-pole components at 30GeV are different from that at 3 GeV due to the magnet saturation. Correction data, which are measured for 96 bend and 216 quadrupole magnets at 30GeV are also included in lattice file. • One octupole and one sextupole are added to straight section for simulation. • Using SAD and MAD program for parameter survey and particle tracking. • 6D full symplectic tracking can be done but 4D tracking was performed for simplicity.

  6. JPARC-MR Lattice + Sextupole & Octupole

  7. Evolution of tune in simulation • The fourth order resonance is assumed to be used. • Change Horizontal tune 0.255 → 0.245 every 50 turns. • We tried several working point for vertical tune. • Vertical tune and the strength of sextupole and octupole are kept constant. • Horz. chromaticity is small ( ξx < 1)

  8. Evolution of Horz. phase space plot nx=0.255 nx=0.250 nx=0.245

  9. Evolution of distribution • Beam emittances for horz. and vert. are assumed as 10 pi mm-mrad. • Parabolic beam distribution is assumed for the initial condition. • Horz. beam distribution in phase space is plotted every 500 turns. • Typically, it takes one hour for 1000 particles and 20000 turns. • The rotation of islands can be adjust to right-angle by changing ocutpole and sextupole position.

  10. Estimation of particles loss at the septum • 5mm septum thickness is assumed here. • The fraction of core particle have about 50%. • Islands fraction: about 10% • 50/1000=0.5% will be lost at septum magnet

  11. 5 pi mm-mrad 10 pi mm-mrad (design) 15 pi mm-mrad Initial beam emittance dependence 1 pi mm-mrad ・Fraction of trapped particles and particle loss at septum magnet depends on initial beam emittance.

  12. K2=2.6 K3=-35 K2=2.0 K3=-90 Parameter survey • We are trying to find good parameter to increase the islands particles. • Sakumi-san found several candidates at nx=0.25. • But no islands are obtained for these parameters in tracking simulation.

  13. Parameter survey nx=0.255 K2=2.0 K3=-90 nx=0.250 nx=0.245

  14. Amplitude dependence of tune • We try to follow CERN experiment to increase islands particles. • CERN group show it is important to erase amplitude dependence of horizontal tune by octupole strength. • K3 is trimmed during crossing 0.25. • This effect was small.Something wrong?

  15. Summary • Multi-turn extraction for JPARC-MR is studied. • Tracking simulation shows • Stable islands can be obtained. • Enough beam separation space between core and islands is obtained • core fraction have 47%. island fraction: 13%. • Beam loss: <1% • Issues • Increase the fraction of islands particles. • Machine error tolerances. • …

More Related