100 likes | 206 Views
Spectrometer Solenoid Update. MICE Video Conference #129 February 25, 2010. Steve Virostek - LBNL. Magnet 2 Modification Summary.
E N D
Spectrometer Solenoid Update MICE Video Conference #129 February 25, 2010 Steve Virostek - LBNL
Magnet 2 Modification Summary • A modification to Magnet 2 has been carried out which adds a single stage cryocooler to provide additional cooling to the HTS leads and won’t require full magnet disassembly • The single-stage Cryomech AL330 cooler provides 170 W at 55 K and required modifications only in the “turret” area • The added cooling power should lower the HTS lead temperature sufficiently to train to full current • The new cooler could remove enough heat to permit the other 3 two-stage coolers to maintain the cold mass LHe level (i.e. closed system) • Additional instrumentation has also been incorporated
Magnet 2 with Added Cryocooler Single-stage cooler Thermal link HTS leads
Modification Details Added turret space Access port
Current Status of Magnet 2 • The Magnet 2 turret area has been modified to allow installation of the single stage cooler • New HTS and warm leads have been tested in an off line apparatus and have been installed in the magnet • Additional temperature sensors on the cold heads (1st and 2nd stages) and voltage taps on the lower HTS leads have been added • Initial pumpdown and leak check of the magnet insulating vacuum has been carried out • Several leaks in the new turret welds were found and are expected to be repaired today • Cooldown will start in one week if leak repairs go well
Magnet 2 Single Stage Cooler Single stage cooler and flexible copper thermal link during fit installation in Magnet 2
Vacuum Pumping of the Magnet Reassembled turret (single stage cooler on right) Mechanical pump with cold trap and increased diameter connection
Magnet Leads Testing • A series of off line lead tests were conducted in order to characterize the warm leads and verify the performance of the HTS leads • The tests were delayed by a vacuum leak in one of the ceramic feedthroughs that was not readily located • The resistive heating in the warm leads was found to be higher than originally predicted; a modified design has been incorporated into Magnet 2 • Lead tests for Magnet 1 are under way and near complete