1 / 24

DAYA (POWER) LISTRIK

DAYA (POWER) LISTRIK. DAYA (POWER) LISTRIK. Adalah jumlah kerja yang dapat dilakukan Dalam setiap detik, dalam satuan Watt atau Joule / detik atau Volt Ampere. P = E . I (Watt) E = I . R (Volt). 2. P = I . R. 2. E. E. I =. P =. R. R.

blaine
Download Presentation

DAYA (POWER) LISTRIK

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DAYA (POWER) LISTRIK

  2. DAYA (POWER) LISTRIK Adalah jumlah kerja yang dapat dilakukan Dalam setiap detik, dalam satuan Watt atau Joule / detik atau Volt Ampere. P = E . I (Watt) E = I . R (Volt) 2 P = I . R 2 E E I = P = R R PT PLN (Persero) Udiklat Pandaan

  3. Daya Listrik yg dikeluarkan oleh Generator. • Daya Aktif, satuan watt, (KW). • Daya Semu, satuan VA, (KVA). • Daya Reaktif, satuan VAR, (KVAR). Faktor daya (Cos φ), adalah perbandingan antara Daya Aktif dan Daya Semu. Watt Cos φ = —— VA

  4. DAYA PADA ARUS BOLAK BALIK Tiga macam Daya : • Daya Aktif (P) • Daya Reaktif (Q) • Daya Semu (S) Segi tiga Daya : P j Cos = S Q S Q j Sin = S j Q j Tan = P P PT PLN (Persero) Udiklat Pandaan

  5. Pengukuran daya 3 phase Teorema Blondel pada pengukuran daya phase banyak. B’ A B WA Z A’ BEBAN Z Z C’ Wc C

  6. TEOREMA BLONDEL Daya dapat diukur dengan mengurangi satu elemen wattmeter dari sejumlah kawat dalam sistem poly phase  ( n – 1 ) wattmeter . dgn syarat: satu kawat hrs dibuat “common” terhadap semua rangkaian potensial. “daya jumlah” : Daya nyata total diperoleh dengan menjumlahkan pembacaan masing masing watt meter secara aljabar.

  7. V AC I A’A Beban Δ: seimbang, induktif, sudut phasa φ, I phasa lagging V phasa I AC V BC I AB φ I BC 30o + φ I CB φ 120o φ I B’B I BA V CB V BA

  8. Pada WA : vektor IA’A = IAC = IAB Pada Wc : vektor IB’B = IBA = IBC Kerana setimbang : VAC = VBC = VBA = V I AC = ICB = IBA = I WA = VAC IA’A cos(30o – φ) V I cos(30o – φ) WB = VBC IA’B cos(30o + φ) V I cos(30o + φ) ________________________________+WA + WB = VI {cos(30o–φ) + VI cos(30o+φ)}

  9. WA+WB = VI {Cos(30o– φ) + VI Cos(30o+ φ)} = {Cos(30o– φ) + Cos(30o+ φ)} V I = (Cos 30o Cosφ + Sin30o Sinφ + Cos30o Cosφ) - Sin30o Sinφ} VI = 2 Cos30o Cosφ V I WA + WB = 2 . ½ V¯3Cosφ V I

  10. R W1 R N W2 S 3 WATTMETER PADA 4 KAWAT S T W3 T N

  11. W2 + W1 = V¯3 V I Cos φ W2 – W1 = V I ( 2 Sin 30o Sinφ ) = V I Sin φ W2 – W1 VI Sin φ -------------- = ----------------------- = (1/V¯3) tg φ W2 + W1 V¯3 V I Cos φ tg φ = {1,73 (W2 – W1)} / (W2 + W1) Cos φ dapat ditemukan yaitu : PF = Cos φ = 1 / {V¯¯(1 + tg2φ)}

  12. Dengan metode 2 wattmeter pada pengukuran daya dalam sistem balanced : Jika : W2 = W1φ = 0 PF = 1 W2 = 2 W1φ = 30o PF = 0,866 W1 = 0 φ = 60o PF = 0,5 W1 = negatif φ > 60o PF = < 0,5