CLIC RF LOAD Preliminary design

CLIC RF LOAD Preliminary design. Load Parameters : freq = 11.9942 GHz Bandwidth = +/- 200MHz Ppeak = 80 MW Paverage = 56 W Tpulse = 140 ns Rep rate = 5 Hz Input flange = WR90 Emax = 51 MV/m Hmax = 144 kA/m. Value from CERN design at 11.424 GHz. CERN design.

ginger
Download Presentation

CLIC RF LOAD Preliminary design

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CLIC RF LOAD Preliminary design LoadParameters : freq = 11.9942 GHz Bandwidth = +/- 200MHz Ppeak = 80 MW Paverage = 56 W Tpulse = 140 ns Rep rate = 5 Hz Input flange = WR90 Emax = 51 MV/m Hmax = 144 kA/m Value from CERN design at 11.424 GHz

  2. CERN design Freq = 11.424 GHz 8.05mm 16.1mm 30mm

  3. CEA proposal : use of rectangularwaveguide for easiermachining WithStainlessSteel 430, sigma = 1.1 E6, mur = 6 a = 12.7 mm b = 10.16 mm PRF = 40 MW Emax = 51.1 MV/m Hmax = 134 MV/m Att = -16.5 dB/m a = 12.7 mm b = 3.4 mm PRF = 13.33MW Emax = 51.1 MV/m Hmax = 134 MV/m Att = -29.4 dB/m L(-3dB)=102 mm a = 12.75 mm b = 3.45 mm PRF = 13.33MW Emax = 48 MV/m Hmax = 125 MV/m Att = -26.1 dB/m L(-3dB)=116 mm a = 12.7 mm b = 1.7 mm PRF = 6.67 MW Emax = 51.1 MV/m Hmax = 134 MV/m Att = -48.8 dB/m L(-20dB)=410 mm a = 12.75 mm b = 1.75 mm PRF = 6.67 MW Emax = 47.7 MV/m Hmax = 124 MV/m Att = -42.7 dB/m L(-20dB)=468 mm

  4. CEA proposal : easiermachining ? Top view 12.7mm 86.2mm 22.86mm 600mm

  5. Stepheightreductionsparameters b1 = 10.16 mm b2 = 3.4 mm bstep = 5.86 mm Lstep = 35.53 mm R1 = 1mm R2 = 1mm a1 = 10.0 mm a2 = 8.0 mm for PRF = 13.33 MW (80 MW / 6) Emax = 52.2MV/m Hmax = 136.3 kA/m Lstep a1 a2 R1 R2 b1 bstep b2 b1 = 3.4 mm b2 = 1.7 mm bstep = 2.40 mm Lstep = 35.53 mm R1 = 0.2mm R2 = 0.2mm a1 = 5.0 mm a2 = 3.0 mm for PRF = 6.67 MW Emax = 52.6MV/m Hmax = 137.3 kA/m