GE DESIGN PROJECT

GE DESIGN PROJECT. Carrie Weinhold Chidi Chukwunenye Jed Gallo Sean Funk. The Objective General Electric is in need of a new design of a telecommunications station powered by sustainable energy and using their new sodium metal halide battery. The Customer.

kaden-lara
Download Presentation

GE DESIGN PROJECT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GE DESIGN PROJECT Carrie Weinhold ChidiChukwunenye Jed Gallo Sean Funk

  2. The Objective General Electric is in need of a new design of a telecommunications station powered by sustainable energy and using their new sodium metal halide battery.

  3. The Customer • Main customer: telecommunications company and their biggest need is for an efficient cost-friendly telecommunications center • Secondary Customers: the citizens of rural town outside of Managua, Nicaragua.

  4. Background Information • Exploring alternate energy sources: Wind Solar Geothermal Micro hydro Best two sources: solar and wind

  5. Target Specifications • Materials Cost- under $120,000 • Off- grid powered • Energy input/output- calculated load=2094.2 Watts • Environmental sustainability • Weather resistant • Decrease use of non-renewable energy

  6. Proposed Solutions Solar Diesel Wind Wind Tronics WT6500 Wind Turbine Kubota GL 7000 Diesel Generator GE Energy GEPV-200, Solar Panel, 200 Watt, 24 Volt

  7. Matrices

  8. Design Solution 72 GE solar panels: 36 pairs in parallel 1 7kW Kubota GL 7000 Diesel Generator

  9. Design Solutions PV ARRAY SIZE: 7.2 kw Generator to Solar Output Generator Info

  10. Cost Analysis Cost of Materials: $114,649.98 Total Cost of Product (installed): $142,548.45