An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Problem with the TL-pump pressure sensor TL_PT104 TL-pump VELO meeting

  2. After maintenance of the TL-pump in November 2011 it showed unusual pressure variations. See vertexMT-meeting of January 19. Lately it exhibits, apart from wiggles in PT104, also a decreasing pressure profile. TR_PT104 TR-pump TL_PT104 26 bar TL-pump 24 bar 2 months VELO meeting

  3. Decided to switch from TL to TLR-pump. Did so on Friday July 27. TR-pump TR-pump TR_PT104 TL_PT104 TL-pump TLR-pump VELO meeting

  4. LHCb will take data till mid December and from January 6 till February 11, 2013. So what are we going to do with the TL-pump ?? nothing and wait for LS1 to repair, i.e. Feb 2013 ? in the TS3 + MD period (Sept. 17 till 30) ? isolate a.s.a.p. TL and repair it, but it is undetermined when we will have the opportunity, and risky because there is no spare (although it is a shaky TL-pump) during the repair. And testing it after repair might be impossible for a week or more. VELO meeting