430 likes | 538 Views
TPC Meeting. Institute of Physics, Academia Sinica Jia-Ye Chen 2007.6.21. Outline. Pile-up Pulse Decomposition Study Pulse Identification, Fitting (Well & Failure) Statistics, Efficiency, Residual and Further more ... Pad Response Function (PRF)
E N D
TPC Meeting Institute of Physics, Academia Sinica Jia-Ye Chen 2007.6.21
Outline • Pile-up Pulse Decomposition Study • Pulse Identification, Fitting (Well & Failure) • Statistics, Efficiency, Residual and Further more ... • Pad Response Function (PRF) • Smearing Effect and Parameterization of PRF • Experimental Measurement & Analysis
Pile-up Pulse Decompisition • Algorithm for Identification • Single Pulse & Shape Parameterization • Pile-up Pulse, Shoulder Pulse and Coupled • Failed Fitting (small pulse, plateau pulse) • Efficiency : Percentage of Pulse • Residual • Question & Problem
Algorithm for Identification • Pile-up Pulse • peakAdc > threshold (dynamic threshold) • Separation of peakTdc > 2 clocks • Pulse valley away from prevPeakTdc > 2 clocks • Shoulder Pulse ( By Su-Yin Wang ) • Δ(ΔADC ) < -8. • Separation to neighboring peakTdc > 3.
Percentage of Pulse ID • number pileup pulse = 76946 • number of single pulse = 41787 (54.31%) • number of double pulse = 33531 (43.58%) • number of triple pulse = 1294 ( 1.68%) • number of quadruple pulse = 334 ( 0.43%) Pileup GOOD • number of good pulse = 2692664 • number of single pulse = 2198194 (81.64%) • number of double pulse = 484378 (17.99%) • number of triple pulse = 7106 ( 0.26%) • number of quadruple pulse = 2986 ( 0.11%)
Percentage of Failure • number of pileup pulse = 54260 • number of single pulse = 30534 (56.24%) • number of double pulse = 22563 (41.58%) • number of triple pulse = 956 ( 1.76%) • number of quadruple pulse = 247 ( 0.46%) • number of (1) pulse =18 (0.0074%) • (percentage in double pulse (0.0177%)) • (chi_square>4 , single pulse) • number of (1+2+3+4) pulse =89 (0.16%) • (percentage in double pulse (0.39%)) • (chi_square>4 , single pulse)
Efficiency & Residual Run 30501 : First 500 Events & only double-pulse event w/o triple-, quadru-, … NEW 1.5 Events/sec OLD 6 Events/sec
Question & Problem • Can we believe the fitting? • Yes, which should be fitted, which not? • Polynomial Approximation, instead of exact Error Function Fitting? • Computing Time : much slower than previous one.
FWHM of the PRF TRIUMF TPC Pad rows are parallel to the sense wire.
Pad Response Function • Width of PRF • Direct measure of the power to distinguish between two close-by coordinates. • Determine the two-track resolution. The induced charge distribution is called “Pad Response Function”.
Parameterization of PRF Under the optimal design of pad width G : the distance between sense wire and cathode plane : chamber-specific pad response width, often normalized to the pad width ΔP by
Smearing Effects to PRF • The transverse diffusion • The angular wire effect • The angle under which the tracks cross the wire-normal. • The E × B effect close to the sense wires • The angular pad effect • If tracks cross the normal on a pad-row under a non-zero angle. • If more than one wire contributes to a pad signal.
Experimental Measurement New TPC Line Fitting (Lab. Frame) By Nakatsugawa Yohei