1 / 28

Product Presentation 2007

Product Presentation 2007. SKY AIR Launch of new Non-Inverter + Duct (R22) series. NEW. Sky Non-Inverter R22 Heat Pump RY-series. +. NEW. Low Static Pressure Duct FDYB. and Medium Static Pressure Duct FDYM. Overview. 1. Product Line-up 1.1 Product Range 1.2 Combination Table

Download Presentation

Product Presentation 2007

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series

  2. NEW Sky Non-Inverter R22 Heat Pump RY-series + NEW Low Static Pressure Duct FDYB and Medium Static Pressure Duct FDYM

  3. Overview 1. Product Line-up 1.1 Product Range 1.2 Combination Table 1.3 Nomenclature 2. Benefits & Features 3. Product Characteristics 3.1 General Specifications 3.2 Operation Range 3.3 Refrigerant Circuit Diagrams 3.4 McQuay/Daikin Name Cross-over 4. Conclusion

  4. 1. Product Line-up 1.1 Product Range • The Non-Inverter RY R22 outdoor series will be available: • in combination with low/medium static pressure duct • in heat pump and with R22 refrigerant • in 1 and 3 phase power supply

  5. 1. Product Line-up 1.2 Combination Table • The indoor/outdoor combination will be available: • in a wide capacity range (2.7kW to 16.4kW) • in only Pair connection

  6. Power Supply V1 : 220-240V, 1ph, 50Hz Y1 : 380-415V, 3ph, 50Hz Series C : C series Capacity 30 : kW x 10 1. Product Line-up 1.3 Nomenclature: Outdoor RY 30 C V1 Model Name & Type R : Outdoor Y : Heat Pump

  7. Series C : C series Capacity 30 : kW x 10 Model Type B : Low static duct M : Medium static duct 1. Product Line-up 1.3 Nomenclature: Indoor - FDY B 30 C - M Model Name F : Indoor D : Ceiling concealed Y : Heat Pump Note: Indoors are 220-204V, 1ph, 50Hz

  8. Double Protection Drainage System By introducing ‘Built In’ double drain pans solution, i.e. primary drain pan and secondary drain pan, water leaking will not be a problem anymore. A drain socket is supplied to connect both drain pans to the drainage pipe. The secondary drain pan will act as a drip pan to block any water that might be dripped down, thus offering an additional protection to the ceiling. So additional drain pan will not be necessary during installation which means more cost saving and easy installation at site. Primary Drain Pan (Polystyrene with High Impact Polystyrene cover) Secondary Drain Pan (with insulation) 2. Benefits & Features Space Saving with Easy & Flexible Installation The height of the unit is low, between 261mm (lowest) and 378mm (highest). Therefore it is offering greatest flexibility in selecting installation location above ceiling. Moreover with its special designed ducting, the installation job becomes easy and the conditioned air can be effectively distributed to every corner of the room to ensure a better air distribution and more pleasant environment for comfort living.

  9. Versatility Different layouts can be ‘created’ so that multiple rooms can be cooled together at the same time by using just one indoor unit. Room Layout 2 Room Layout 1 Room Layout 3 Easy Maintenance The simple design concept has a friendly maintenance and servicing in mind. By just removing the secondary drain pan and drain guide, you can access to all the internal parts from the bottom of the unit. No water will flow down when removing the secondary drain pan, making the servicing work very easy. 2. Benefits & Features Elegance and Low Noise Level The indoor unit is installed above the ceiling with only the supply and return air grille exposed to view. This ceiling concealed type of design has made it an elegant model without sacrificing the precious floor space, the air-conditioned space will appear as elegant and prestigious as centralized air-conditioned area, but with only a fraction of the cost. Further the casing is well insulated internally to reduce noise level.

  10. Electrical Control Capability All series are equipped with a wired Electronic SLM Remote Controller. The SLM features: an ON/OFF switch, temperature setting (16°C to 30°C), operation modes (auto/cool/dry/heat/fan), fan speed selection, timer (setting range between 1 to 10 hours), air swing and ‘Sleep Mode’. It is possible to make use of the AC-5300 infrared Remote Controller (in option) to communicate with the SLM Remote Controller. 2. Benefits & Features

  11. 3. Product Characteristics Low Static Pressure Duct – 1 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  12. 3. Product Characteristics Low Static Pressure Duct – 1 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  13. 3. Product Characteristics Low Static Pressure Duct – 3 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  14. 3. Product Characteristics Medium Static Pressure Duct – 1 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  15. 3. Product Characteristics Medium Static Pressure Duct – 1 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  16. 3. Product Characteristics Medium Static Pressure Duct – 1 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  17. 3. Product Characteristics Medium Static Pressure Duct – 3 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  18. 3. Product Characteristics Medium Static Pressure Duct – 3 phase 3.1 General Specifications GENERAL INDOOR OUTDOOR

  19. Heating 3. Product Characteristics 3.2 Operation Range • In cooling: +19°C / +46°C • In heating: -9°C / +18°C Cooling

  20. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYB/M30C RY30CV1

  21. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYB/M40C RY40CV1

  22. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYB/M60C RY60CV1

  23. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYB/M71C RY71CV1

  24. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYM80C FDYB/M90C RY80CV1

  25. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYM80C FDYB/M90C RY90CV/Y1 FDYM100C FDYB/M125C RY100CV1 RY125CV/Y1 FDYB/M140C RY140CY1

  26. 3. Product Characteristics 3.3 Refrigerant Circuit Diagrams FDYB/M160C RY160CY1

  27. 3. Product Characteristics 3.4 McQuay/Daikin Name Cross-over

  28. An outdoor unit with a wide operation range (to +46°C in cooling and -9°C in heating), combinable with low / medium static indoors and available in 1 and 3 phase power supply versions. A product combination with a wide capacity range going from class 30 to 160 (2.7kW to 16.4kW) offering comfort living, greatest flexibility and easiness in installation locations, good COP/EER and static pressure. An indoor unit that is elegant, space saving (lowest height is 261mm), with 4 fan speeds and a well insulated casing to reduce noise level. Moreover it has a ‘Double Protection Drainage System’ to offer an additional protection to the ceiling and easy maintenance. 4. Conclusion With the introduction of the new Non-inverter (R22) Heat Pump RY-series in combination with the Low & Medium Static PressureDuct (FDYB/FDYM), Daikin extends its Sky Air product portfolio for R22 refrigerant and widens its choice for ceiling concealed applications in area’s using R22 units. Mainly the RY + FDYB/M series will provide:

More Related