Irradiation of one CMS ceramic hybrid from Dorazil in Karlsruhe Frank Hartmann IEKP - Universität Karlsruhe (TH) Tracker Week April 2002
Installation • Initial positioning by laser pointer • Scanning with 1mm row steps (10cm/s) • Proton current: 2 mA • 26 MeV protons • Irrad. of 120x120mm2 up to 1e14 p/cm2 takes 20min Tracker Week April 2002
Stability of Beam Current Tracker Week April 2002
Homogeneity of Scanning Scan Area Area of Interest Area cut for dosimetry Autoradiography picture Tracker Week April 2002
Irradiation of Hybrid • During irradiation: Clock, Trigger (10Hz), Error Buffer Readout (1Hz), Reset • Irradiation with 2mA protons up to 2.7e14 p/cm² (~30years LHC) at RT • First qualification at cyclotron with over 5m cables and provisional readout • Hybrid is still activated (2µSv) • Result: Hybrid still alive Tracker Week April 2002
Picture of Hybrid on Ni foil Area cut for dosimetry Hybrid Tracker Week April 2002
Pedestal (peak) before & after After Before Tracker Week April 2002
Noise (deconv) before & after After Before Tracker Week April 2002
Noise (peak) before & after After Before Tracker Week April 2002
Calib (deconv) before & after After Calibration: only first shot! Still working! To be further investigated in the lab! Before Tracker Week April 2002