PICCO Technology Clinical use of parameters

Le but fondamental de nos traitements est d’assurer un transport d’oxygène suffisant aux organes vitaux Transport d’oxygène Debit cardiaque Taux d’hémoglobine Saturation de l’hémoglobine en oxygène Ensuite nous devons contrôler si ce transport suffit au patient !

efia
Download Presentation

PICCO Technology Clinical use of parameters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Le but fondamental de nos traitements est d’assurer un transport d’oxygène suffisant aux organes vitaux Transport d’oxygène Debit cardiaque Taux d’hémoglobine Saturation de l’hémoglobine en oxygène Ensuite nous devons contrôler si ce transport suffit au patient ! Fonctions (reins, par ex) SvO2 Lactatémie

  2. PICCO Technology Clinical use of parameters

  3. Courbe de thermodilution Délai, amplitude, pente, vitesse de disparition Débit cardiaque

  4. Injection de l’indicateur Débit cardiaque Index cardiaque (3 à 5 L/min/m2) Volume télé-diastolique global (700-800 mL/m2) Volume sanguin intra-thoracique (800-1000 mL/m2) Eau pulmonaire extra-vasculaire (3-7 mL/kg)

  5. Calibration et analyse du contour Débit cardiaque continu Index cardiaque continu (> 2,5 L/min/m2) Volume d’éjection (> 35 mL/syst/m2) Variation de la pression pulsée (<10%) Variation du volume d’éjection (<10%) Résistance Vasculaire Systémique I (1700-2400)

  6. IC (l/min/m2) VSTI (ml/m2) EPEI (ml/kg) Thérapie Objectif VSTI EPEI (réaction lente!) < 750 < 3.0 > 1000 < 750 > 1000 > 3.0 < 10 V+ 850-1000 > 10 V+ (!) temporaire 750-850 < 10 < 10 V+ (!) cat > 10 cat V- (!) temporaire 750-850 < 10 < 10 V+ (!) 850-1000 > 10 V+ (!) temporaire 750-850 < 10 < 10 OK > 10 V- (!) temporaire 750-850 < 10 VSTI: 750-1000 VVE EPEI Rx Th Diurèse IC Lactate Extrémités

  7. Surveillance par appareil PICCO - ! L’allumer, le regarder, le critiquer, l’intégrer, l’interpréter - ! N’évalue pas les pressions centrales - ! N’évalue pas la SvO2 - ! Ne « remplace » donc ni la SWAN ni l’Echocardio - ! Tout changement important exige une recalibration -Index cardiaque -Index volhémiques -pulmonaire -volume circulant