An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electron selection and p rejection with the NCC Vasily Dzhordzhadze University of California,Riverside Forward Upgrades Meeting BNL, August 02, 2004 V.Dzhordzhadze

  2. 10 GeV electron in 40 Layer Si/W Calorimeter V.Dzhordzhadze

  3. de/dx in Silicon for Section 1 V.Dzhordzhadze

  4. de/dx in Silicon for Section 2 V.Dzhordzhadze

  5. de/dx in Silicon for Section 3 V.Dzhordzhadze

  6. Fitting of de/dx , NCC Sec1 V.Dzhordzhadze

  7. Fitting of de/dx , NCC Sec2 V.Dzhordzhadze

  8. Fitting of de/dx , NCC Sec3 V.Dzhordzhadze

  9. Fitting of rms , NCC Sec1 V.Dzhordzhadze

  10. Fitting of rms , NCC Sec2 V.Dzhordzhadze

  11. Fitting of rms , NCC Sec3 V.Dzhordzhadze

  12. c2 distribution • c2 Estimator for NCC Si (ei - < ei >)2 / rms2i = 1, 3 V.Dzhordzhadze

  13. c2 distribution for 1 Gev e V.Dzhordzhadze

  14. c2 distribution for 1 Gev p V.Dzhordzhadze

  15. c2 distribution for 5 Gev e V.Dzhordzhadze

  16. c2 distribution for 5 Gev p V.Dzhordzhadze

  17. c2 distribution for 10 Gev e V.Dzhordzhadze

  18. c2 distribution for 10 Gev p V.Dzhordzhadze

  19. c2 distribution for 20 Gev e V.Dzhordzhadze

  20. c2 distribution for 20 Gev p V.Dzhordzhadze

  21. c2 distribution for 40 Gev e V.Dzhordzhadze

  22. c2 distribution for 40 Gev p V.Dzhordzhadze

  23. Electron selection /p rejections in % • c2 cut 5.0 7.5 10.0 1GeV 83.2/100 93.3/99.1 97.4/78.0 5GeV 78.1/100 88.9/100 93.1/100 10GeV 76.2/100 87.1/100 92.2/100 20GeV 79.5/100 88.1/100 91.9/100 40GeV 76.7/100 85.1/100 89.8/100 V.Dzhordzhadze

  24. Summary • A good electron selection is achievable with NCC, same time having almost 100% pion rejection in momentum interval 1-40 GeV/c • A study of NCC performance continues… V.Dzhordzhadze