Estimate of Heating of Modular Coil From Un-Insulated VV during Bakeout

Estimate of Heating of Modular Coil From Un-Insulated VV during Bakeout. Estimate of Heat Load Estimate of LN2 heating based on heat balance Estimate of Coil and Clamp Heating. Estimate of Un-insulated Coil Heating by 350 C VV. Assumptions. Radiative Heating Only

page
Download Presentation

Estimate of Heating of Modular Coil From Un-Insulated VV during Bakeout

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Estimate of Heating of Modular Coil From Un-Insulated VV during Bakeout • Estimate of Heat Load • Estimate of LN2 heating based on heat balance • Estimate of Coil and Clamp Heating

  2. Estimate of Un-insulated Coil Heating by 350 C VV

  3. Assumptions • Radiative Heating Only • Based on Emissivity of VV and Clamps/Coils = 0.3 • Effective Heat Flux 1500 w/m2 • LN2 Coiling in Tubes • Convection off base of MCWF Max Temperatures Clamp 206 K Coil 108 K

  4. Temperature Sensitivity to Emissivity

  5. Can we detect an un-Insulated VV during Bakeout to 150C? • Simple 1 unit cell model of VV Shell • Heated by Bakeout tubes mounted to one corner • Radiatively cooled to Modular Coils at 80K • Emissivity assumed 0.4 • Higher Values would be easier to detect • Also Radiatively Heated on inside by rest of VV at 150 C • Ignores Conduction from adjacent cells • Representative of Large Un-insulated region • Small Un-insulated regions will be harder to detect

  6. ~8” (20cm) ~8” (20cm) Representative Region of VV VV with Bakeout Heating Tubes Courtesy of Mike Cole

  7. Portion of Un-insulated VV Exposed to 80K Coil Assumes Only Lower Corner at 150 C dT ~ 34 C