An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 350MHz RFWaveguide Air Personnel Safety System Dave Bromberek March 3, 2008

  2. Outline • System Operation and Layout • Failure Modes • 3 Year Calibration

  3. System Operation • Pressurization of the 350MHz waveguide system in Bldg. 420 is used as THE means of providing rf radiation personnel protection in the event of a breach of the waveguide system (see also technical note “Measurements of RF Power Radiated From Open WR2300 Waveguide Flanges” – D.Horan 7/3/05). • Blowers on the rf cavities provide cooling air to the input couplers and also slightly pressurize the waveguides to ≈ 3-4”H2O (≈ .1-.15 psi.). The pressure is monitored and interlocked by eight waveguide photohelic pressure gauges, one or more of which is capable of detecting a waveguide flange gap of .185”, in all available waveguide switching modes. • A trip of any waveguide photohelic will shutdown all five 350MHz klystron stations. • Orphan photohelics are installed at RF1 and RF3 to provide protection in these areas when the stations are switched off-line. • Additional photohelics monitor cavity blower pressure (Not Interlocked).

  4. System Layout • Two blowers supply cooling air to the input coupler and slightly pressurize the waveguide. • Each cavity’s blower manifold is monitored by a photohelic. • Cavity blower pressure is alarm only • Each sector’s waveguide is monitored by a photohelic. • Waveguide air pressure is a PSS interlock and will trip all 5, 350MHz rf stations.

  5. System Layout

  6. System Layout • There are two blowers on each rf cavity, one being redundant. The cavity photohelics are on a scale on 0” – 10”H2O and read 10” or better with both blowers at full speed. • Blowers are fed from two 120VAC power circuits/sector. Each cavity blower pair is fed from a separate circuit.

  7. System Layout • Waveguide photohelics are on a scale of 0” – 5”H20 and normally read between 3” - 4.5”H2O. • Pressure sampling port is located on a section of waveguide in Bldg. 420 (see drawing)

  8. System Layout • Photohelic gauges are individually fused. • A 24VDC power supply feeds the setpoint contacts from the cavity gauges to Allen/Bradley Fuse 24VDC Power Supply

  9. System Layout

  10. Blower Control Screen From RF Panel – Select Sector Blower AC Power Circuits Cavity Photohelic Setpoint Contacts

  11. RF6 Waveguide Air PSS Screen • From RF Panel - Misc/Tools

  12. OAGapps Data • From x-term type OAGapps

  13. OAGapps Data

  14. OAGapps Data

  15. OAGapps Data

  16. OAGapps Data

  17. Failure Modes Symptoms Steps Problem

  18. Failure Modes Symptoms Steps Problem

  19. Failure Modes • Cavity photohelic hoses CAN be disconnected and connected to an adjacent gauge to eliminate the photohelic as the culprit. • NEVER disconnect the waveguide photohelic hose unless the rf stations are already down due to a WG Air PSS trip. • If it is determined that a waveguide photohelic is the problem, or the system is tripped on waveguide air, a work request and CCWP must be submitted and approved. C2 C1 C4 WG C3

  20. Failure Modes Symptoms Steps Problem

  21. Failure Modes Symptoms Steps Problem

  22. Failure Modes Symptoms Steps Problem

  23. 3-Year Calibration & Testing • See “Technical Note on the Testing of the 350MHz Waveguide Air Personnel Safety System” – D. Bromberek 10/21/05 • Test and adjust setpoints • Requires the opening/closing of five waveguide flanges (one at each station), in twelve waveguide switching modes – 60 iterations • Data is recorded and setpoints chosen • .185” uniform gap in a waveguide flange trips RF6 PSS System • .185” gap is detected by at least one photohelic in every waveguide configuration • Loss of one cavity blower does not trip the PSS • Loss of two cavity blowers does trip the PSS (Not always possible) • Validation and sign-off of CCWP requires tripping each of the eight waveguide photohelics one at a time, and verifying that it trips ALL FIVE STATIONS.

  24. 3-Year Calibration & Testing .185” Spacers .185” spacers in use

  25. 3-Year Calibration & Testing Data Collected @ RF3 – May 2005

  26. 3-Year Calibration & Testing Simplified Data From RF3 – May 2005

  27. 3-Year Calibration & Testing • Calibration due spring shutdown ’08.