FRAP Measure the intracellular (HeLa) diffusion of: EGF (membrane bound) GFP in cytosol

Group 3a Alessandro Borgia Juliane Winkler. FRAP Measure the intracellular (HeLa) diffusion of: EGF (membrane bound) GFP in cytosol. FRAP: membrane bound EGF-receptor. TIME (AFTER BLEACHING). t=100 ms. t=1000 ms. t=1500 ms. t=3000 ms. t=0. FRAP: membrane bound EGF receptor. ROI.

payton
Download Presentation

FRAP Measure the intracellular (HeLa) diffusion of: EGF (membrane bound) GFP in cytosol

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Group 3a Alessandro Borgia Juliane Winkler FRAP Measure the intracellular (HeLa) diffusion of: EGF (membrane bound) GFP in cytosol

  2. FRAP: membrane bound EGF-receptor TIME (AFTER BLEACHING) t=100 ms t=1000 ms t=1500 ms t=3000 ms t=0

  3. FRAP: membrane bound EGF receptor ROI whole cell intensity (cell) mean fluorescence intensity Background (BG) Time (sec)

  4. cell ROI background mean fluorescence intensity Time (sec) EGF-receptor the average intensity of the prebleach image is set to 1 FLUORESCENCE RECOVERY CURVE

  5. Increasing the ROI 1 4

  6. Cytosolic GFP PREBLEACH TIME (AFTER BLEACHING) = 130 ms TIME (AB) = 195 ms TIME (AB) = 455 ms

  7. Cytosolic GFP

  8. TROUBLESHOOTING (or troubles shooting at us, you decide...) 1ST BLEACHING - SIGNAL POOR  ENOUGH LASER POWER  ADJUSTED TO MAX DATA STILL VERY NOISY - HOW TO IMPROVE IT? HIGHTEN PHOTOMOLTIPLICATION OR GAIN INCREASE SPOT AREA  INCREASES OVERALL SIGNAL INTENSITY • BUT IT TAKES LONGER TO FULLY RECOVER THE FLUO  LONGER EXPOSURE TO IMAGING LASER • HIGHER PHOTOBLEACHING OF THE WHOLE CELL FROM IMAGING LASER  DID NOT WORK OPTIMIZATION OF THE ACQUISITION ALTOGETHER: REDUCE SCANNING AREA („CLIPPING“) ADJUST BLEACHING TIME TO TRIGGER THE BLEACHING WHEN THE SCANNER IS VERY CLOSE TO THE BLEACHED SPOT INCREASE PIXEL SIZE AND TRIED TO SCAN BIDIRECTIONALLY - LOSE RESOLUTION! FOR CYTOSOL ONLY  OPEN THE PINHOLE FULLY - INCREASES SIGNAL AND IS LESS SENSITIVE TO MOTION ALONG Z-AXIS (NO DEFOCUSING PROBLEMS).

  9. THANKS TO: Stefan Terjung Christian Tischer YOU ALL