1 / 18

D. Still All Experimenters Meeting Dec 21, 2009

Crystal Collimator Studies in the Tevatron T-980 Collaboration: FNAL, SLAC, BNL, CERN, PNPI, IHEP, INFN. D. Still All Experimenters Meeting Dec 21, 2009. Outlook. Quick Crystal Collimation Explanation Recent System Additions/Changes Channeling for the new O-05-09 crystal.

Download Presentation

D. Still All Experimenters Meeting Dec 21, 2009

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Crystal Collimator Studies in the TevatronT-980 Collaboration:FNAL, SLAC, BNL, CERN, PNPI, IHEP, INFN D. Still All Experimenters Meeting Dec 21, 2009

  2. Outlook • Quick Crystal Collimation Explanation • Recent System Additions/Changes • Channeling for the new O-05-09 crystal. • Collimating Volume Reflected (VR) Beam at F172H collimator. • Beam Plans for 2010 AEM - Dec 21, 2009 - D. Still

  3. 1 2 5 Ray Fliller- Halo 03 Explanation of Crystal Channeling AEM - Dec 21, 2009 - D. Still

  4. T980 Work Jan-April 2009 Multistrip crystal: both volume reflection (F172) and multi-channeling (E03) work at Tevatron Miscut angle: make it small (≤ 0.2 mrad) and negative for partial or full channeling Also used crystal collimation for 4 HEP stores to gain operational experience and understanding of efficiency. AEM - Dec 21, 2009 - D. Still

  5. New Vertical Goniometer Up and Downstream Motion control and LVDT Up and Downstream Laser angle measurement instruments AEM - Dec 21, 2009 - D. Still

  6. T980 Setup in Tevatron E0 for 2009-2010 F1 F172H Collimator Horizontal Volume Reflected Beam (VR) Path B0 23.731 m 33.115 m E03H Collimator Channeled Beam Path Bent Crystal E0 D0 Removed B2-3 dipole Installed new Vertical goniometer with 2 crystals 4 m upstream of the Horizontal gonoimeter Also Installed new detectors And hardware at F17 to dectect Volume reflected beam (VR) AEM - Dec 21, 2009 - D. Still

  7. Goniometer Installations over Summer 09 Shutdown Newly built and installed (Summer 2009) Vertical goniometer at E0. It is ~ 4m upstream of the Hor. one. Ver. goniometer houses old O-shaped crystal (reversed for negative miscut) and multi-strip crystal. Modified horizontal goniometer. Replaced old large-miscut angle O-shaped crystal with new small miscut O-shaped during Summer 2009. AEM - Dec 21, 2009 - D. Still

  8. New Characterized Crystals Name: O-01-09 Bend: 315urad Miscut:195urad New New Name: MS-08-09 Bend: 63urad (VR) Broken during installation Installed VerDnstrmgoniometer Name: O-05-09 Bend: 360urad Miscut: 120urad New Name: O-BNL-02 Bend: 410urad Miscut: 1600 urad Installed Horgoniometer Installed VerUpstrmgoniometer AEM - Dec 21, 2009 - D. Still

  9. Outlook • Quick Crystal Collimation Explanation • Recent System Additions • Channeling for the new O-05-09 crystal. • Collimating Volume Reflected (VR) Beam at F172H collimator. • Beam Plans for 2010 AEM - Dec 21, 2009 - D. Still

  10. First 980-GeV Beam Test with New Hor Crystal New detector at F17 Channeled beam (abort gap) Channeled into E03 collimator channel AEM - Dec 21, 2009 - D. Still

  11. E03H Coll Scan compare 2005,2008,2009O-BNL-02 to O-05-09 crystals New Hor Crystal Previous used BNL Crystal AEM - Dec 21, 2009 - D. Still

  12. Compare BNL to O-05-09 2008 O-BNL-02 sigma=30 urad 2009 O-05-09 sigma = 16 urad AEM - Dec 21, 2009 - D. Still

  13. Outlook • Quick Crystal Collimation Explanation • Recent System Additions • Channeling for the new O-05-09 crystal. • Collimating Volume Reflected (VR) Beam at F172H collimator. • Beam Plans for 2010 AEM - Dec 21, 2009 - D. Still

  14. VR Beam at F172H Collimators VR Beam should be ~ .9mm from core For ~ VR angle of 16urad. Result of ring orbit for 16urad Kick simulating effect of VR kick. AEM - Dec 21, 2009 - D. Still

  15. November 2, 2007 A.Drozhdin At E03H Collimator At F172H Collimator Extracted and circulating beams position in the Tevatron at collimation in horizontal plane with 3-mm channeling crystal located at EO straight section. Transverse plane is shown at EO3 (left) and F172 (right) collimators entrance for particles with momentum dP/P=0 (top), dP/P=-0.0002 (middle) and both (bottom).

  16. Finding VR beam at F17 Maybe Collimated VR beam Displacement difference ~ 45 mils or 1.125 mm F172H scan w/ angle at channel -970urad. F172H scan w/ angle at VR -882urad AEM - Dec 21, 2009 - D. Still

  17. F172H Collimation CH,VR,AM beam AEM - Dec 21, 2009 - D. Still

  18. Summary & Continued Beam Studies • Encouraged thus far by results of O-05-09, still need some instrumentation improvements at F17 to help detect the VR beam. • Still are working on front end software for the vertical goniometer. • Once vertical goniometer is ready, there will be a number of EOS requests. • Investigate 2 plane crystal channeling. • Investigate use of crystal collimation with a multi-strip crystal. AEM - Dec 21, 2009 - D. Still

More Related