An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2012 Lik KaiPacific Sense March 2012

  2. PACIFIC SENSE • Company Intro

  3. PACIFIC SENSE

  4. Comparison of FM200 system against room volume

  5. Suppression Solutions • The latest technology in suppression system suitable for Hospital Building • Selection criteria • Types of product • Design and installation • Maintenance • Quality

  6. Selection criteria • Physical dimensions • Occupant • Weight / space limitations • Fire fighting performance • Environmental • Life cycle cost

  7. Types of product • Fixed gaseous fire suppression system • Chemical gases • Inert gases • Carbon Dioxide • Fixed water system • Water mist • Sprinkler • Water spay system

  8. Fixed gaseous fire suppression systems • Chemical gases

  9. Fixed gaseous fire suppression systems • Inert gases

  10. Fluid Safety and Use Concentration Comparison

  11. Fire Protection Fluid Environmental Properties Comparison

  12. Fixed gaseous fire suppression systems • Carbon dioxide • Over eighty years • Extinguishes the fire primarily by reducer the oxygen concentration and provides localized cooling • Local application and total flooding application

  13. Fixed water system • Water mist • 90% droplets less than 1 mm in diameter • To cool the fire source by removing the heat and suppressing the fire • Displaces oxygen in the atmosphere

  14. Design and installation • Complex and various of size • Type of fuel • High value asset • Temperature • Downtown • Integration • Safety

  15. Maintenance • Regular maintenance by competent , third party certified person • Manufacturer instruction • Charges to protection area • Enclosure integrity • Nozzles position

  16. Quality • Design : Factory trained and certified engineer • Component : US DOT , EU TPEP and PED • System : UL , FM Global , LPCB and Vds • Installation : NFPA 2001 , ISO 14520 and the manufacturer instruction

  17. Thank You